Sunday, 21 April 2013

Bypass Separators


Bypass Separators

Bypass separators fully treat all flows generated by rainfall rates of up to 6.5mm/hr. This covers over 99% of all rainfall events. Flows above this rate are allowed to bypass the separator. These separators are used when it is considered an acceptable risk not to provide full treatment for high flows, for example where the risk of a large spillage and heavy rainfall occurring at the same time is small.
Surface water drains normally discharge to a watercourse or indirectly into underground waters (groundwater) via a soakaway. Contamination of surface water by oil, chemicals or suspended solids can cause these discharges to have a serious impact on the receiving water.

The Environment Regulators, Environment Agency, England and Wales, SEPA, Scottish Environmental Protection Agency in Scotland and Department of Environment & Heritage in Northern Ireland, have published guidance on surface water disposal, which offers a range of means of dealing with pollution both at source and at the point of discharge from site (so called ‘end of pipe’ treatment). These techniques are known as ‘Sustainable Drainage Systems’ (SuDS).
Where run-off is draining from relatively low risk areas such as car-parks and non-operational areas, a source control approach, such as permeable surfaces or infiltration trenches, may offer a suitable means of treatment, removing the need for a separator.
Oil separators are installed on surface water drainage systems to protect receiving waters from pollution by oil, which may be present due to minor leaks from vehicles and plant, from accidental spillage.
Effluent from industrial processes and vehicle washing should normally be discharged to the foul sewer (subject to the approval of the sewerage undertaker) for further treatment at a municipal treatment works.
Separator Standards and Types
A British (and European) standard (BS EN 858-1 and 858-2) for the design and use of prefabricated oil separators has been adopted. New prefabricated separators should comply with the standard.
Separator Classes
The standard refers to two ‘classes’ of separator, based on performance under standard test conditions.
Class I
Designed to achieve a concentration of less than 5mg/l of oil under standard test conditions, should be used when the separator is required to remove very small oil droplets.
Class II
Designed to achieve a concentration of less than 100mg/l oil under standard test conditions and are suitable for dealing with discharges where a lower quality requirement applies (for example where the effluent passes to foul sewer).
Both classes can be produced as full retention or bypass separators. The oil concentration limits of 5 mg/l and 100 mg/l are only applicable under standard test conditions. It should not be expected that separators will comply with these limits when operating under field conditions.

Epurblock P6


Epurbloc P6 Super Low Profile will serve up to 6 persons
The Epurbloc P6 Super Low Profile from Tricel is the new super low shallow septic tank to hit the market.
Epurbloc P6 is so small in size it can be easily installed with just a mini digger and dropped into place.
Key Benefits;
  • Reinforced ribs allows the Epurbloc to be installed in a granular backfill
  • Advanced Eco Medium Filter prevents blockages from occurring
  • Overall depth only 1.4m
  • EN12566-1 European certified
  • Transportable by van or transit due to size and durability
Dimensions
  • Height - 1.4m
  • Length - 2.7m
  • Width - 1.1m
Manhole extensions for deeper installations or sloping sites are available and are simply screwed onto the lid. Up to 3 extension pieces maybe used.
A pair of 180mm riser pieces are priced at £35
Delivery prices may very depending on site location - please call us on 01923 261660

Thursday, 18 April 2013

Klargester Sigma Shallow Range


Klargester Sigma Shallow Septic Tank - 2,800l

Klargesters engineers have recently completed the design and testing process of their next generation shallow dig septic tank range, which will drastically reduce installation costs by up to as much as 50% of an ordianry septic tank.
The Klargester Sigma septic tank will drastically reduce the time and cost of a septic tank installation.
Features & Benefits
  • Pea gravel backfill for dry sites
  • EN 12566-1 approved
  • Installation in hard rock areas where deep digs are not possible
  • 30mm between inlet and outlet
  • 0.5 and 1m neck extensions available for deeper installations
The Klargester Sigma is a stock item and is typically be available within 3 working days to any site In the UK

Monday, 15 April 2013

Spring Sale


Spring Sale

Great savings on Klargester BioDisc's, Klargester Biotec's & Klargester E Range of sewage treatment plants.

Also with any Klargester sewage treatment plant purchase we will throw in a free alarm to suit worth £186!

This Spring we are also giving away a free high level alarm with every Klargester or Clearwater pump station order over the value of £1,200

With all Klargester orders we can deliver to an UK mainland site within 3 working days and offer a free of charge Hi-Ab offload on all Klargester sewage treatment plant.

Check out our website for more great deals this Spring with half price Klargester sample chambers, rainwater harvester, and Klargester spare parts.


Thursday, 11 April 2013

Klargester Biosafe



The best designs are the simplest. So if you require trouble free sewage treatment, your sure to be impressed with the new Biosafe from Klargester.
Fluidised, fixed-film biozones are used as the operating process, resulting in a cleaner, quieter and more efficient treatment plant.
A new generation of treatment plants for treating domestic sewage waste in a compact system of three separate stages within a ‘unitank’ design. The fluidised fixed-film biozone process provides an extremely robust means of reducing ammoniacal nitrogen.
Raw sewage flowing to the unit is received in the primary settlement zone. Gross solids settle to the bottom.
The residual effluent (supernatant liquor) is displaced from the primary stage into the two-stage biozone.
Flow circulation in the biozone is generated by the effect of a fine bubble system. During several passes through the beds, the supernatant liquor is purified by naturally occurring micro organisms (biomass) that grow on the media. The liquid displaced to the outlet is treated, and known as final effluent.
Benefits
  • Unobtrusive below ground installation
  • Suitability for varying invert levels
  • 450mm & 750mm invert options
  • Excellent durability
  • Low profile results in shallow depth excavation - saving on average 50% on installation costs
  • Simple maintenance with easy desludging
  • Pumped discharge availabale
  • Compliant with BS EN-12566
  • Discharge quality of 20:30:10
Product Specification
  • Inlet - 450mm
  • Outlet - 550mm
  • Length - 2.7m
  • Height - 1.7m
  • Diameter - 1.5m

Monday, 1 April 2013

Septic Tank Conversions Kit - Marsh Uni:Gem


Marsh Uni:Gem 6
Marsh Uni:Gem

The Marsh Uni:Gem 6 serves up to a maximum of 6 people
Converts your old septic tank into a sewage treatment plant
The Uni:Gem unit can be retrofitted to existing septic tanks and failing sewage treatment plants saving hundreds of pounds on purchasing new systems and installing new soakaways.
Installing the Uni:Gem will give you a superior discharge standard which can be designed to suit most discharge requirements from the local water company or Environment Agency.
The Uni:Gem range is designed in engineered glass fibre moulds, to provide the optimal conditions for the formation of biomass for the breakdown of raw sewage. The result of the process will meet current UK legislation together with the future EN standard EN12566-3Marsh Industries is at the fore front of product develop in the sewage and effluent treatment industry.
A minimum effluent quality of 20:30:20 should be achieved.
Marsh Uni:Gem 2 - Converts Your Septic into a Sewage Treatment Plant
Benefits;
  • Silent compressor with housing
  • Variable inverts available
  • Easy de-sludge access
  • Low maintenance costs
  • Compressor alarm & RCD box included free of charge
  • Designed to meet EN12566-6
  • Pump options available
The Uni:Gem only requires a granular or peashingle surround as long as site conditions are faverouable.
Dimensions;
  • Height - 2.2m
  • Diameter - 1.1m
  • Weight - 195kg (Empty)
  • Power - 80w
For more information or prices please call us on 01923 261660 or check out our website