Showing posts with label Online Builders Merchant. Show all posts
Showing posts with label Online Builders Merchant. Show all posts

Tuesday, 12 April 2016

Building Regulations

Building Regulations

Siting
Septic tanks and holding tanks should be located at least 7m away from any habitable part of a building & preferably down slope.
Sewage treatment plants can sometimes be allowed to be as close as 5m, but must be agreed with a building inspector.
There are adequate means of access for emptying & maintenance (emptying usually requires hard ground within a distance of 30m)
drainage field or mound should be ideally located 10m from any watercourse or building

Thursday, 8 May 2014

Septic Tank Supplies Supply Allsands Builders Merchants

Septic Tank Supplies have supplied Allsands builders merchants with two Zoeller Maxi 1,000 litre sewage pump stations at their two branches in Kent.

Zoeller Maxi - 1000L - Up To 5m Lift

he Zoeller Maxi sewage lift pumping station is complete "job ready" product for use in areas where gravity flow is not available. It is used for various drainage applications, with the maxi system also used for the transfer of sewage or waste water, all specially designed for easy installation.
What’s included;
1 x 1/2 HP WU222 Automatic cast iron 50mm solids sewage pump (upto 6m lift)
1 x 1000mm x 1500mm poly moulded basin
1 x 5 ton rated 750mm x 750mm galvanised manhole cover
1 x Quiet non return valve
1 x Lifting chain
1 x Internal 50mm PVC discharge pipe work kit
1 x seal for incoming and outgoing pipework
1 x 12 months warranty

Applications;
•Single dwellings
•Large extensions
All our pumping stations comply to BS EN 12050-1:2001 / BS EN 752-6:1998 standards.